Design of a new laser thickness measurement instrument

  • Corresponding author: ZHAO Bin, zhaobin63@yahoo.cn
  • Received Date: 2010-12-20
    Accepted Date: 2011-10-22
  • In order to measure the thickness of the hot-rolled steel plate on line, an automatic laser gauging system was established, and its mechanical design and optical design, image algorithm based on MATLAB were investigated. Firstly,the laser beam was inclined to project onto the side of the plate,and a baffle is setted to block the part of light at horizon.Secondly, the laser spot on the tested plate is imaged to CCD target surface in an industrial video camera.Then the defocusing amount is calulated based on the the CCD images.Finally,according to the geometric relationship between actual thickness of the plate to be measured and the imaging height of the plate flank in the CCD and the defocusingamount, the thickness of the steel plate is calculated. Experimental results indicate that the precision of the system is 0.32mm, smaller than the measurement system requirements 0.5mm when the plate thickness between 8mm and 120mm. This measuring system has less influence induced by high temperature radiation.It can satisfy the system requirements of stabilization,higher precision and rapidity,as well as little interference.
  • 加载中
  • [1]

    JIA Z G,LU Z G.Online testing technology of thickness[J].Instrumentation Technology,2009(2):19-21(in Chinese).
    [2]

    ZHU Q F,ZHANG X Y,LI S A.Application of X-ray measuring technique in hot strip mill[J].Nondestructive Testing,2008,30(5):321-323(in Chinese).
    [3]

    BAI S J.JGC-H1A laser thickness gauge in the application of Handan iron and steel plate[J].Shandong Metallurgy,2004,26(s1):281-282(in Chinese).
    [4]

    ZHAO B,WANG D,XIONG Zh Y.A kind of plate thickness of laser measurement device:China,CN101825438A[P].2010-09-08(in Chinese).
    [5]

    WANG W,CHEN H X.Inhibiting noise of light spot image[J].Laser Technology,2007,31(1):54-57(in Chinese).
    [6]

    SHEN M D,ZHANG M,ZHANG F Q.Effection of defocused image on area measurement and error amendment[J].Acta Photonica Sinica,2009,38(5):1240- 1244 (in Chinese).
    [7]

    MA G G,CHANG J.Research on the influence of the defocus on the optical measurement[J].Ship Electronic Engineering,2008(9):28-32(in Chinese).
    [8]

    LIU W,HAN X D,AI H.Application of laser triangulation in displacement measurement[J].Optics and Precision Engineering,2004,12(4):103-107(in Chinese).
    [9]

    WANG P,LIU F Y.The study on the reliability of the PLC automatic control system[J].Electric Drive,2001(1):36-38(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(4052) PDF downloads(833) Cited by()

Proportional views

Design of a new laser thickness measurement instrument

    Corresponding author: ZHAO Bin, zhaobin63@yahoo.cn
  • 1. Department of Instruments, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China

Abstract: In order to measure the thickness of the hot-rolled steel plate on line, an automatic laser gauging system was established, and its mechanical design and optical design, image algorithm based on MATLAB were investigated. Firstly,the laser beam was inclined to project onto the side of the plate,and a baffle is setted to block the part of light at horizon.Secondly, the laser spot on the tested plate is imaged to CCD target surface in an industrial video camera.Then the defocusing amount is calulated based on the the CCD images.Finally,according to the geometric relationship between actual thickness of the plate to be measured and the imaging height of the plate flank in the CCD and the defocusingamount, the thickness of the steel plate is calculated. Experimental results indicate that the precision of the system is 0.32mm, smaller than the measurement system requirements 0.5mm when the plate thickness between 8mm and 120mm. This measuring system has less influence induced by high temperature radiation.It can satisfy the system requirements of stabilization,higher precision and rapidity,as well as little interference.

Reference (9)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return