Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 35 Issue 2
May  2013
Article Contents
Turn off MathJax

Citation:

Optimization of high precision rhomb-type achromatic retarders

  • Received Date: 2010-04-22
    Accepted Date: 2010-06-17
  • In order to improve precision of rhomb-type achromatic A/4 phase retarders,based on the positive and negative delay error of A/4 phase retarders and larger refractive index,high precision retarders were designed.The retarder was analyzed and validated in experiments,and the data of high precision λ/4 phase retarder were obtained.It is shown at the retardation curve within the range of 350nm to 2000nm that retardation is 90°at two wavelengths and the maximal retardance error is smaller than 0.04°.Comparing with conventional retarders,the new retarder not only extends achromatic range,but also improves achromatic precision.The results are helpful to design high precision λ/4 phase retarders.
  • 加载中
  • [1]

    JEAN-BAPTISTE M,GUILHEM G.Terahertza chromatic quarter wavcplates[J].Applied Optics,2006,31 (2):265-267.
    [2]

    McINTYRE C M.Achromatic waveplates for the visible spectrum[J].Journal of the Optical Society of America,1968,58 (12):1575-1580.
    [3]

    CHUN Y.Construction of an optical rotator using quarterwave plates and optical retarders[J].Optical Engineering,1995,34 (10):3031-3035.
    [4]

    SONG L K,LI G H.Design of the three-element combination achromatic retarder made of mica and quarz[J].Journal of Optoelectronics·Laser,2000,11 (1):51-53 (in Chinese).
    [5]

    YUN M J,LI G H,WANG W,et al.Three-in-one composite achromatic λ/4 wave-plate[J].Journal of Optcelectronics·Laser,2001,12(6):562-564(in Chinese).
    [6]

    Li J Zh.Optical handbook[M].Taiyuan:Science and Technology Press of Shanxi,1986:576-580 (in Chinese).
    [7]

    LI G L,SONG L K,HAO D Zh,et al.Optical design of rhomb-type achromatism retarder[J].Laser Technology,2006,30 (5):539-540(in Chinese).
    [8]

    LI G L,SONG L K,HAO D Zh,et al.Sensitivity of rhomb-type phase retarders to the input angle[J].Laser Technology,2008,32(2):157-158(in Chinese).
    [9]

    ZHAO P T,LI G H,WU F Q.New design of high precision achromatic phase retarder[J].Acta Optica Sinica,2005,25 (7):980-983(in Chinese).
    [10]

    WANG X,WU F Q,LIANG Zh X.A new λ/4 phase retarder insensitive to the angle of incidence[J].Journal of Optoelectronics·Laser,2000,11 (2):154-156(in Chinese).
    [11]

    NAGIB N N.Phase retardars with variable angles of total internal reflection[J].Applied Optics,1994,33(7):1218-1222.
    [12]

    NAGIB N N.Phase retarders highly insensitive to the input angle[J].Applied Optics,1998,37 (7):1231-1235.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(4347) PDF downloads(643) Cited by()

Proportional views

Optimization of high precision rhomb-type achromatic retarders

  • 1. Department of Physics, Xingyi Normal University for Nationalities, Xingyi 562400, China;
  • 2. Institute of Laser Research, Qufu Normal University, Qufu 273165, China;
  • 3. Department of Physics and Engineering Technology, Sichuan University of Arts and Science, Dazhou 635000, China

Abstract: In order to improve precision of rhomb-type achromatic A/4 phase retarders,based on the positive and negative delay error of A/4 phase retarders and larger refractive index,high precision retarders were designed.The retarder was analyzed and validated in experiments,and the data of high precision λ/4 phase retarder were obtained.It is shown at the retardation curve within the range of 350nm to 2000nm that retardation is 90°at two wavelengths and the maximal retardance error is smaller than 0.04°.Comparing with conventional retarders,the new retarder not only extends achromatic range,but also improves achromatic precision.The results are helpful to design high precision λ/4 phase retarders.

Reference (12)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return