Test method of detection sensitivity of starring laser detecting systems

  • Received Date: 2008-11-20
    Accepted Date: 2009-03-02
  • In order to study the detection sensitivity of a starring laser detecting system, considering the features of the starring laser detecting system and the fact that the detected laser energy varying with different view field angle, based on the available measure condition in laboratory,an indirect method was presented to test the detection sensitivity in laboratory. Probable problems in each part of the design were analyzed, and their resolution methods were put forward accordingly. Based on the experimental setup, experiments were carried out and the detection sensitivity was obtained at seven view angles.the detection sensitivity in center view field reaches 0.259nJ/cm2 with a relative deviation of 3.4%~4.2%. The measurement error was also theoretically analyzed. The test results confirm that the method is feasible and practical, and the accuracy meets the requirement. This method is useful for the design of high precision test systems.
  • 加载中
  • [1]

    WANG Y Zh.Fish eye lens optics[M].Beijing:Science Press,2006:12-16(in Chinese).
    [2]

    WANG Y Zh.Modern military optics technology[M].Beijing:Science Press,2003:387-389(in Chinese).
    [3]

    WANG Y Zh,ZHOU B,HE Y Q,et al.Laser spot location in imaging laser detecting systems[J].Laser Technology,2008,32(3):248-251(in Chinese).
    [4]

    GONG F A,ZHOU Y F,ZANG Sh H,et al.The outdoor test method of laser warning equipment[C]//The 12th Academic Annual Meeting Cllection in Electronic Countermeasure Branch of Chinese Electronic Society.Beijing:Chinese Electronic Society,2001:717-718(in Chinese).
    [5]

    State Bureau of Quality and Technical Supervision.GB/T13584-92 Parameter measurement for infrared detector[S] .Beijing:Standards Press of China,1992(in Chinese).
    [6]

    LIU H,ZHU R H,ZHU Y,et al.Semiconductor photo detector spectro-photoelectrical sensitivity test[J].Journal of Nanjing University of Science and Technology,1999,23(2):129-131(in Chinese).
    [7]

    WU Q B.Research on parameters-automatic-measurement system of the quarter infrared optic-electronic detector[D] .Wuhan:Science& Technology of Huazhong University,2005:9-10(in Chinese).
    [8]

    CHENG Y B,LI Q,LIU Sh Q.A novel design for laser orientation detection system[J].Laser Technology,2005,29(5):538-540(in Chinese).
    [9]

    SU D T.Optics testing technology[M].Beijing:Beijing Institute of Technology Press,1996:104-106(in Chinese).
    [10]

    SHI Ch W,SUI Q Q,SHI B Y.A new automatic test system of reaction time and detection[J].Electro-optic Technology Application,2008,23(1):38-40(in Chinese).
    [11]

    FAN Zh G.Photoelectric testing technology[M].Beijing:Publishing House of Electronic Industry,2004:4-7(in Chinese).
    [12]

    MIU J D,XU W J,MOU T Sh.Photoelectric technology[M].Hangzhou:Zhejiang University Press,1995:54-56(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(4361) PDF downloads(316) Cited by()

Proportional views

Test method of detection sensitivity of starring laser detecting systems

  • 1. Department of Optics and Electron Engineering, Ordnance Engineering College, Shijiazhuang 050003, China

Abstract: In order to study the detection sensitivity of a starring laser detecting system, considering the features of the starring laser detecting system and the fact that the detected laser energy varying with different view field angle, based on the available measure condition in laboratory,an indirect method was presented to test the detection sensitivity in laboratory. Probable problems in each part of the design were analyzed, and their resolution methods were put forward accordingly. Based on the experimental setup, experiments were carried out and the detection sensitivity was obtained at seven view angles.the detection sensitivity in center view field reaches 0.259nJ/cm2 with a relative deviation of 3.4%~4.2%. The measurement error was also theoretically analyzed. The test results confirm that the method is feasible and practical, and the accuracy meets the requirement. This method is useful for the design of high precision test systems.

Reference (12)