Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 33 Issue 4
Aug.  2009
Article Contents
Turn off MathJax

Citation:

Methods for obtaining high-quality reconstructed image of particles

  • Corresponding author: CAO Na, cnt96@vip.sina.com
  • Received Date: 2008-04-25
    Accepted Date: 2008-07-04
  • In order to understand the effect of the system factors,such as light intensity,magnification,CCD and background,on the reconstructed image of different diameter particles in the process of holographic reconstruction,a series of experiments were performed.The experimental results showed that,by adjusting the light intensity and making the background light intensity closed to the lower limit of CCD threshold,images with smoothing background and high definition were acquired.For particles with diameter less than 20μm and a reconstruction system with a certain magnification,a little higher intensity of reconstruction light was needed for ideal images.It was favorable for image keeping the experimental environment dark.Results show that high quality particle images can be obtained by means of the above methods in the process of particle holographic reconstruction.
  • 加载中
  • [1]

    THOMPSON B J.Holographic methods for particle sizing and velocity measurement-recent advances[J].Proc SPIE,1989,1136:308-326.
    [2]

    YAMAKAWA M,KAMIKAWA M,YOSHIZAKI T,et al.Measurement of droplet distribution of a D.I.Gasoline spray with pulsed laser holography[J].Transaction of Socisty of Automotive Engineers of Japan,2001,32(4):45-50.
    [3]

    TRONLINGER J D.Particle field holography[J].Opt Engng,1975,14(5):383-392.
    [4]

    VOSSING H J,BORRMANN S,JAENICKE R.In-line holography of cloud volumes applied to the measurement of raindrops and snowflakes[J].Atmospheric Research,1998,49(3):199-212.
    [5]

    SORENSON D S,MINICH R W,ROMERO J L,et al.Ejecta particle sizing distributions for shocked loaded Sn and Al metals[J].J A P,2002,92(10):5830-5836.
    [6]

    O'HERN T J,KATZ J,ACOSTA A J.Holographic measurements of cavitation nuclei in the sea[R].New York:The American Society of Mechanical Engineers,1985:39-42.
    [7]

    COIMBRA C F M,RANGEL R H,TROLINGER J D.The science behind spaceflight holography investigation in a virtual apparatus[R].Reston,USA:American Institute of Aeronautics and Astronautics,2001:1-17.
    [8]

    LUO Zh X,LI Z R,LI Z Y,et al.An automatic segmenting method for restructied image of high speed particle field[J].Acta Photonica Sinica,2007,36(3):503-506(in Chinese).
    [9]

    PHIPPS G S,ROBERTSON C E,TAMASHIRO I M.Reprocessing of nonoptimally exposed holograms[J].Appl Opt,1980,19(5):802-811.
    [10]

    ULIBARRENA M,MENDEZ M J,BLAYA S,et al.Anomalous D-Log E curve with high contrast developer Kodak D8 on ultra fine grain emulsion BB640[J].Optics Express,2001,9(12):645-651.
    [11]

    VIKRAM Ch S.Optimizing image quality in fraunhofer holography with variable intensity reconstruction beam[J].Optik,1990,86 (2):58-60.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3953) PDF downloads(169) Cited by()

Proportional views

Methods for obtaining high-quality reconstructed image of particles

    Corresponding author: CAO Na, cnt96@vip.sina.com
  • 1. Northwest Institute of Nuclear Technology, Xi'an 710024, China;
  • 2. Department of Physics, Xi'an Armed Police ForceAcadmy, Xi'an 710012, China

Abstract: In order to understand the effect of the system factors,such as light intensity,magnification,CCD and background,on the reconstructed image of different diameter particles in the process of holographic reconstruction,a series of experiments were performed.The experimental results showed that,by adjusting the light intensity and making the background light intensity closed to the lower limit of CCD threshold,images with smoothing background and high definition were acquired.For particles with diameter less than 20μm and a reconstruction system with a certain magnification,a little higher intensity of reconstruction light was needed for ideal images.It was favorable for image keeping the experimental environment dark.Results show that high quality particle images can be obtained by means of the above methods in the process of particle holographic reconstruction.

Reference (11)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return